Applicability

Link G4X MonsoonX; earlier G4+ Monsoon uses another guide.

Model and software

MonsoonX uses one A connector, four injector, four ignition and six auxiliary outputs. It has no internal throttle motor driver; unused injector outputs are not ordinary auxiliary switches.

I/O and electrical limits

Allocate the MonsoonX’s 4 digital inputs and auxiliary channels according to the actual functions required. On V3.0 and later hardware, the knock input uses the DI4 pin, which cannot also serve as a digital input.

Functions and electrical specifications
ItemSpecification / revision condition
Model / part number127-4000
Engine configuration4 cylinders / 2 rotors sequential with direct spark
Injector outputs4
Ignition outputs4
Auxiliary outputs6
Analogue inputs4
Digital inputs4
Temperature inputs2
Trigger inputs / signal2
Manifold pressureBuilt-in MAP
Data logging512 MB; 250 channels; aggregate rate up to 100 kHz
Software / communicationPCLink G4X / Mini-B USB
CAN communication1
Connector / termination34-pin Superseal / 4-1437290-0
Operating supply6.5–24 V DC
Maximum input voltage36 V maximum; normal operation remains 6.5–24 V
Operating current200 mA
Maximum continuous current draw3 A
Sensor power outputs+5 V
Analogue voltage signal range0–5 V from sensors or external controllers
Engine-control functionsFlex fuel, VVT, open / closed-loop boost and dual closed-loop lambda; I/O allocation required
Knock input and hardware revisionV3.0+ only; shares pin 6 with DI4. Earlier hardware has no internal knock control
Electronic throttle motor controlNo built-in E-throttle motor driver in this model

Shared pins and revision conditions

On V3.0 and later, internal knock input shares pin 6 with DI4. Earlier hardware lacks this internal knock function. Do not count knock and DI4 as separate simultaneous inputs.

Sensor and driver connections

Connect sensor ground, power ground, 5 V reference and 0–5 V signals to their assigned pins. Match trigger type and edge, ignition power stages, and injector / solenoid impedance and current.

Reference documents

Link G4X MonsoonX — Quickstart Guide
Document language: English
Referenced chapters: Connector allocation, power, triggers, auxiliary outputs and PCLink