Applicability
Applies to the stated manufacturer reference model; wiring must match the actual hardware revision.
Model and software
G4+ Monsoon uses connector A and PCLink G4+. It lacks internal wideband control, throttle motor drive and knock input. Later MonsoonX hardware features do not apply.
I/O and electrical limits
First allocate pins for the 4 injection outputs, 4 ignition outputs and auxiliary functions. Monsoon has no throttle motor driver; a 3-wire idle valve requires both Aux 1 and Aux 2.
| Item | Specification / revision condition |
|---|---|
| Version identification | Link G4+ generation |
| Injector outputs | 4 |
| Ignition outputs | 4 |
| Analogue inputs | 4 |
| Temperature inputs | 2 |
| Digital inputs | 4 |
| Auxiliary outputs | 6 |
| Data logging | 4 MB; verify the hardware revision |
| Wideband lambda | No internal wideband controller; use a compatible external controller |
| Electronic throttle | No internal E-throttle |
| Connector / termination | A |
| Software / communication | PCLink G4+ |
| Trigger inputs / signal | 2 inputs; reluctor, proximity, optical or Hall, configured for the engine |
| Analogue voltage range | 0–5 V sensor / external-controller signals |
| Sensor power outputs | +5 V |
| Temperature sensor type | NTC thermistor inputs; use the matching pull-up / calibration settings |
| Knock inputs | G4+ Monsoon has no internal knock-sensor input |
| Spare output reuse | Spare ignition outputs may be auxiliaries; spare injection outputs cannot switch general loads |
| CAN / hardware revision | 1 CAN bus |
| Auxiliary-output allocation | Aux 1 / 2 support high-frequency PWM or VVT; three-wire idle uses both |
Sensor and driver connections
Connect sensor ground, power ground, 5 V reference and 0–5 V signals to their assigned pins. Match trigger type and edge, ignition power stages, and injector / solenoid impedance and current.
PCLink and first-start checks
Install the matching PCLink generation and drivers, then preserve the existing map and firmware details. Check static sensors, I/O tests, cranking sync and locked ignition timing. The matching F1 help explains detailed settings.
Reference documents
- Link G4+ Monsoon — Quickstart Guide
- Document language: English
- Referenced chapters: Connector allocation, power, triggers, auxiliary outputs and PCLink