Applicability

Link G4X FuryX; do not substitute the earlier G4+ wiring file.

Model and software

FuryX uses A and B connectors, eight injector and six ignition outputs. It includes one Bosch LSU 4.9 wideband driver; dual closed-loop lambda in software does not mean two internal sensor drivers.

I/O and electrical limits

A shared pin can perform only one function at a time. Check physical pin overlap when allocating CAN, digital inputs, throttle and auxiliary outputs.

Functions and electrical specifications
ItemSpecification / revision condition
Model / part number122-4000
Engine configuration6 sequential cylinders / 3 rotors
Injector outputs8
Ignition outputs6
Auxiliary outputs10
Analogue inputs9
Digital inputs10; two consumed by the second CAN bus
Temperature inputs4
Trigger inputs / signal2
Knock inputs2
CAN communication2
Wideband lambdaOne onboard Bosch LSU 4.9 controller interface
Electronic throttleOnboard E-throttle
Data logging512 MB; 250 channels; aggregate rate up to 100 kHz
Software / communicationPCLink G4X / LTW 6-pin USB
Connector / termination2 × 34-pin Superseal / 4-1437290-0, 4-1437290-1
Operating supply6.5–24 V DC
Maximum input voltage36 V maximum; normal operation remains 6.5–24 V
Operating current200 mA
Maximum continuous current draw8 A
Sensor power outputs+5 V and +8 V
Analogue voltage signal range0–5 V from sensors or external controllers
Engine-control functionsFlex fuel, VVT, open / closed-loop boost and dual closed-loop lambda; I/O allocation required
Acceleration sensingBuilt-in three-axis accelerometer
E-throttle output allocationAux 9 / 10 used by the throttle motor; unavailable for other simultaneous loads

Shared pins and revision conditions

When Aux 9 / 10 drive the electronic throttle, they cannot drive other loads. CAN2 uses DI9 / DI10 pin positions; review network and digital-input assignments together.

Sensor and driver connections

Connect sensor ground, power ground, 5 V reference and 0–5 V signals to their assigned pins. Match trigger type and edge, ignition power stages, and injector / solenoid impedance and current.

Reference documents

Link G4X FuryX — Quickstart Guide
Document language: English
Referenced chapters: Connector allocation, power, triggers, auxiliary outputs and PCLink